FRESENIUS 2008K MANUAL PDF

FRESENIUS 2008K MANUAL PDF

We have 6 Fresenius Medical Care K manuals available for free PDF download: Troubleshooting Manual, Operator’s Manual, Technical Manual. View and Download Fresenius Medical Care K operator’s manual online. K Hemodialysis Machine Operator’s Manual. K pdf manual download. FRESENIUS K OPERATORS MANUAL KHOXJMBJNW | PDF | 45 Pages | KB | 06 Apr FRESENIUS K OPERATORS MANUAL.

Author: Gardajinn Brabei
Country: Uganda
Language: English (Spanish)
Genre: Spiritual
Published (Last): 14 December 2011
Pages: 249
PDF File Size: 20.59 Mb
ePub File Size: 5.30 Mb
ISBN: 891-6-92508-156-9
Downloads: 15231
Price: Free* [*Free Regsitration Required]
Uploader: Zulurr

Post Temperature Sensor Calibration Be sure to use aseptic technique for all bloodline connections.

Administer saline as prescribed. Troubleshooting Alarms and Troubleshooting Page 200k8 Sodium I have the new PM sheets, but I don’t have the new manual. In some cases, the operator must reset them.

FRESENIUS MEDICAL CARE K OPERATOR’S MANUAL Pdf Download.

Page 30 The Adult size comes standard with the K and manuall accommodate patients with msnual arm circumferences of centimeters. The operator can start or stop the pure UF option at any time. Page 88 This is the average UF rate at this point in the treatment ml. Organization Of The k Page Diasafe Plus Filter A means of filtering the dialysate to reduce bacteriological and endotoxin exposure Auto Heat Disinfect Allows the user to program the K hemodialysis machine to automatically run a heat disinfection program according to a schedule.

This will minimize the possibility of the segment kinking during pump operation. Product Improvement Policy Page Dialogue Box displays the current 2008m, patient blood pressure and pulse and the time taken. The book begins with an overview that introduces the operator to the major components and describes how they are organized on the machine.

  GAME CHANGER AG LAFLEY PDF

Arterial Pump Rate The contents of this document may not be disclosed to third parties, copied, or duplicated in any form, in whole or in part, without the prior written permission of Fresenius Medical Care. Page 26 The fluid level has dropped below the sensors in the venous drip chamber.

Fresenius Medical Care K Manuals

Inlet Water Pressure Regulator Anybody check out the first paragraph on the first page of the latest PM manuals? Allow system to cycle using approximately ml of saline. Completion Of Dialysis K Minor Blood Leak? Your request is being processed Blood Pressure Module This chapter covers all cleaning, disinfection, and maintenance tasks that can be performed by the operator.

The Control Panel Chapter 1—Overview The Control Panel The control panel see Figure 3 is located at the top, front of the K machine and contains key pads that allow the user to control the operation of the Maunal machine. K Dial Valve Failure 1 Electronic self-test failure. Any machine can be set up for a pre-pump or post-pump arterial chamber, or single-needle dialysis requiring two blood pumps by adding modules, or rearranging their order.

The machine must only be operated in accordance with these instructions.

  BESARKAN ZAKAR PDF

Observe the system for fluid leaks and discontinue treatment if you are unable to correct any fluid leak quickly. The TMP alarm limits are spread during the test. To automatically turn the machine off after the Auto Heat Disinfect program runs, select the Off after Heat Disin option in Mznual Mode see figure Active Topics in this Category.

Page RBV e. If the machine fails these tests and the cause cannot be corrected, it should not be used for treatment.

Fresenius Medical Care 2008K Operator’s Manual

Page Error copying data into Flash ROM Alarm If this message occurs in dialysis mode, take the blood pump module Blood Pump Message while in service mode out of service and alert a qualified technician. Fill Program—Occurs when water level in the air separation chamber gets too manuual.

Page After all of the constituents are correctly entered and the name of the concentrate has been chosen, touch the Enter Conc screen button to verify that the concentrate was entered into the list. Because the machine uses a closed, volumetric ultrafiltration system, the TMP is monitored primarily for detecting large shifts in pressure.