FORNEY IGNITER PDF

FORNEY IGNITER PDF

The HESI is a Class 3 Igniter used for direct spark ignition of oil or gas igniters, small burners, and combustion turbines. Forney’s High Energy Spark Igniter (HESI) provides a highly reliable, non-fouling source of ignition for oil or gas igniters or small burners. The Forney horn igniter is designed to be a direct replacement for the OEM igniter on tangentially fired boilers. This igniter features improvements such as the. The MAXFire® Series gas igniter incorporates the “protected primary combustion zone” design in each of the 5 capacities available. MAXFire® gas igniters provide the most reliable source of energy for main flame ignition, flame stabilization, and boiler warm-up.

Author: Terg Vuzshura
Country: Oman
Language: English (Spanish)
Genre: Technology
Published (Last): 22 January 2015
Pages: 10
PDF File Size: 7.60 Mb
ePub File Size: 5.51 Mb
ISBN: 204-8-85114-148-2
Downloads: 43162
Price: Free* [*Free Regsitration Required]
Uploader: Arak

As part of the multi-discipline SPS team, Forney engineers met with the plant personnel to explain the igniter parts assembly and operations. Class 3 Specia Approval: The controlled mixture of fuel and air in the primary combustion zone results in a highly reliable, stable igniter flame.

The dual fuel horn igniter fires either oil or gas without a change of equipment, allowing for a quick and effortless change over of fuel. The problem solving approach was based on the PDCA Plan-Do-Check-Adjust model identifying specific actions, checks, and adjustments to be carried out before scheduled outages.

This Class I igniter is located in a tilting tangentially fired boiler adjacent to the main fuel nozzle.

Replacement of the spark tip is quick and easy. Natural gas or propane Minimum Length: Forney and plant personnel did further root cause analysis to identify additional adjustments and countermeasures. As a gas igniter, the gas is directed to the tip through the single flexible tube.

  AHU VALIDATION IN PHARMA PDF

MaxFire® Series Gas Igniter – Forney Corporation

The spark rod features a self-cleaning surface-gap spark tip that is easily replaceable via a threaded connection. Application Flexibility The protected ihniter combustion zone ensures reliable operation in multiple environments. The ignition process starts inside the guide tube away from the burner environment resulting in an extremely stable and reliable igniter.

Flexible Single Tube igniher. It is also the choice when both air and steam atomization is required for No. The HESI produces a consistent spark due to its foul resistant design, while the optical detector proves flame without physical contact.

Flexible Single Tube igniters. The HESI spark tip is a ignkter, surface-gap tip which is replaceable as a unit by a threaded connection. It is also the choice when both air and steam atomization is required for No.

ignitdr Both rigid and flexible spark rods can be provided with an optional retraction assembly to allow the spark tip to be inserted and retracted from the firing position. Flexible Single Tube This Class I igniter is located in a tilting tangentially fired boiler adjacent to the main fuel nozzle. The remaining HESI components consist of a positioning rod, cable and power unit.

Most applications require no igniter retraction reducing installation costs and ongoing maintenance. The HESI is a Class 3 Igniter used for direct spark ignition of oil or gas igniters, small burners, and combustion turbines. Q87 Igniter The Q87 igniter is the best choice when dual fuel natural gas and No. An ATEX version is also available. The ignition process starts inside the guide tube away from the ignlter environment resulting in an extremely stable and reliable igniter.

  BUNHEADS BOOK PDF

Forney provides a complete line of oil and natural gas igniters for all burner types.

The Forney horn igniter is designed to be a direct replacement for the OEM igniter on tangentially fired boilers. The collaborative multidisciplinary partnership between AEP and Forney was able to successfully address the igniter reliability concerns within a few months and improved plant efficiency.

Horn Igniter

This Class I igniter is located in a tilting tangentially fired boiler adjacent to the main fuel nozzle. WC across device Length:. Low Maintenance requirements No moving parts, a self-cleaning spark tip and no tools required to perform periodic inspection Durability Igniher duty material and no moving parts to wear out. An ATEX version is also available.

Oil Igniter Reliability Optimized by AEP-Forney Team

Low Maintenance Requirements No moving parts, a self-cleaning spark tip and no tools required to perform periodic inspection. With a change-out of the internals, the Q87 can switch from firing one fuel to another. The spark rod is available in the standard rigid design or in a flexible configuration for use in a tilting tangential burner application. Stainless steel with a silicon carbide insulator Maximum Tip Temperature: Return to top of page. Product Overview Product Overview The Q is a self-contained Class 1 oil or gas igniter used for burner ignition, stabilization or boiler warm-up.

The Q87 igniter is the best choice when dual fuel natural gas and No.