ASTM D, Bearing Capacity of Soils for Static Load & Spread Footings – Download as PDF File .pdf), Text File .txt) or read online. Find the most up-to-date version of ASTM D at Engineering In each increment; the load stays static for 15 minutes according to ASTM D 94 specification. The results showed that the plate settlements of the soil under.

Author: Tygokazahn Mausar
Country: India
Language: English (Spanish)
Genre: Sex
Published (Last): 23 April 2010
Pages: 210
PDF File Size: 3.99 Mb
ePub File Size: 13.69 Mb
ISBN: 652-4-15080-569-6
Downloads: 21979
Price: Free* [*Free Regsitration Required]
Uploader: Vudojinn

Register now while it’s still free! In rock, plates larger than mm diameter may be used, depending on the jointing frequency. Plate Load testing is usually used for the verification of the bearing capacity of the land of the substrate, of the foundation layer and the base layer of the flooring, although it is not uncommon to its use to investigate the bearing capacity of the soil surface or to the state compaction of granular materials and road surfaces.

The Settlement-Recording Devices, such as dial gauges should be able to measure to an accuracy of at least 0. The details of equipment including the certificates of instrument and copies of calibration charts from approved agency and setup for conducting the plate load test shall be submitted for the approval by the Engineer before commencement of sstm test.

Click Here to join Eng-Tips and talk with other members!

Close this window and log in. The plate load test shall be carried out at locations as shown in the drawings or as directed by the Engineer using approved equipment. This test was rarely done for this purpose anymore. Defense manufacturing is all about project manufacturing and project accounting.

plate load test – Soil testing engineering – Eng-Tips

The plate bearing load test shall be discontinued if any of the following occurs: Subcommittees responsible for standards develop can withdraw a standard if they consider that it has limited continued use value. By joining you are opting in to receive e-mail. For bearing plates, three circular steel bearing plates, not less than 25mm in thickness and varying in diameter from mm to mm including the minimum and maximum diameter specified or square ast, bearing plates of equivalent area.

  COMPUTER VISION IMAGE PROCESSING SCOTT E UMBAUGH PDF

Promoting, selling, recruiting, coursework and thesis posting is forbidden. Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework. The load transmission takes place via the application of a force by means of a hydraulic system of thrust, of a circular plate.

Download Now White Paper: The applied load shall be measured using calibrated electronic load cell. It’s easy to join and it’s free.

Of fundamental importance, in any case, is the use of the proper contrast medium whose mass is a function of the expected load. Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden. A standard may be withdrawn with or without replacement. The reference beam and measuring devices should be protected from the direct rays of the sun and from wind by means of tarpaulins or other forms of shelter, to minimize errors of measurement which can easily arise from these causes.

The load test consists in transmitting to the soil to be tested and the subsequent increasing load increments, detecting simultaneously the sagging and therefore allows to directly determine a form of deformation or compressibility of the soil.

As an alternative, three small concrete footings of the size mentioned or larger can be cast in-situ. There are two active plate load tests that can be used Resources Digital Transformation may be defined in a number of different ways by analysts or enterprise software vendors. The Hydraulic or Mechanical Jack Assembly should have sufficient capacity to provide and maintain the maximum estimated load but not less than 50 tons in any case. Red Flag This Post Please let us know here why this post is inappropriate.

  BELDEN 9116 PDF

The subsidence induced by the ground plate are simultaneously detected by centesimal or digital data acquisition systems, integral with a frame of astmm outside the area of influence of the applied load. Precise leveling optical survey to accuracy of 0. Download Now Defense manufacturing is all about project manufacturing and project accounting.

Are you an Engineering professional? Join your peers on the Internet’s largest technical engineering professional community.

ASTM makes withdrawn standards available for informational purposes. Thank you for helping keep Eng-Tips Forums free from inappropriate posts. Digital Transformation may be defined in a number of different ways by analysts or enterprise software vendors.

Plate Load Testing

Such footing must have a depth of not less than two thirds of their width. Students Click Here Join Us! Miscellaneous Apparatus required, asstm loading columns, steel shims, and other construction tools and equipment required for preparation of the test pits and loading apparatus.

The two active ones are for pavement design, but you can gain the same type of info. In addition to the continuous listing of all time, load, and settlement data for each test, the report shall include at least d11194 followings:.