Can be used to test the relative resistance to corrosion of aluminium alloys when exposed to a changing climate of acetic acid salt n287, followed by air drying, followed by high humidity, all at an elevated temperature.

Test specimens are placed in an enclosed chamber, and exposed to a changing climate that comprises of the following 3 part repeating cycle.

Sorry. You need to upgrade your browser

The first climate cycle comprises of a continuous indirect spray of neutral pH 6. Test specimens are placed in an enclosed ashm, and exposed to a changing climate that comprises of the following 2 part repeating cycle. ASTM G85 annex A3 – seawater acidified test, cyclic Can be used to test the relative resistance to corrosion of coated or uncoated aluminium alloys and other metals, when exposed to an changing climate of acidified synthetic seawater spray, followed by a high humidity, both at an elevated temperature.

Salt mist cyclic sodium chloride solution. This acceleration arises through the use of chemically altered salt spray solutions, often combined with other test climates and in most cases, the relatively rapid cycling of these test climates over time. There are a number of international test standards available that describe various methods of salt spray, fog, or aetm corrosion tests in detail.

Sometimes referred to as salt fog, or corrosive atmosphere testing salt spray testing encompasses a wide variety of test standards and methods, depending upon product application. Though believed to be accurate at the time of writing, this may change over time.

  CITITORUL BERNHARD SCHLINK PDF

Website design by Peter Bourne Communications. H287 most appropriate test cycle and spray solutions are to be agreed between purchaser and seller.

ASTM B – 74 Method of Acetic Acid-Salt Spray (Fog) Testing (Withdrawn )

You need to upgrade your browser You are using Internet Explorer 8 This is considered an out of date browser. The test was originally developed by the U Atsm Navy to simulate exfoliation corrosion on aircraft carriers. This is followed by 1.

This is followed by 2. The second climate cycle comprises of 0. So this information should not be used as a substitute for referring to a complete test standard, at an appropriate revision level. This test was developed by F. These tests have evolved to address the need for a corrosion atsm capable of replicating the effects of naturally occurring corrosion and accelerate these effects.

Contact Ascott for Further Information.

BASS Equipamentos

The number of cycle repeats and therefore the test duration is variable. But we haven’t supported older browsers like IE8. Can be used to test the relative resistance to corrosion of decorative chromium plating on steel and zinc based die castings, when exposed to an acetic acid salt spray climate at an elevated temperature.

A long standing use of salt spray testing is metal qualification, different metals degrade at varying rates when exposed to corrosive environments. Salt spray tests and its use in ranking stainless steel. The International Stainless Steel Forum provides an in-depth article on the use of salt spray testing for stainless steel, you can find the article here: This climate is maintained under constant steady state conditions.

This website has been developed with modern browsers in mind to allow it to display at its best in a wide variety of viewing situations – including mobile viewing.

This test was originally published as ASTM G43, and is used to determine corrosion resistance in a severe marine atmosphere. This is considered an out of date browser. Please note The test standard summaries are for general guidance only. Test Conditions ASTM G85 annex A1 — acetic acid salt spray test, continuous Test specimens are placed in an enclosed chamber and exposed to a continuous indirect spray of acidified pH 3. Which one you apply will depend mainly upon your products application.

  AHMED DEEDAT THE CHOICE PDF

Exfoliation testing determines the rate at which corrosion products form and fall away from the body of the test sample. ASTM G85 annex A2 – cyclic acidified salt spray test Can be used to test the relative resistance to corrosion of aluminium alloys when adtm to a changing ast of acetic acid salt spray, followed by air drying, followed by high humidity, all at an elevated temperature.

This is followed by 0. Test specimens are placed in an enclosed chamber, and exposed to 1 of 2 possible changing climate cycles.

In this context they can be considered to be equivalent and interchangeable terms. Salt spray testing is conducted to determine the products resistance to corrosion, it is often conducted at the product level to provide quick feedback to the development team on coatings, enclosures and connectors. The following list provides a summary of the international salt spray test standards we can apply:.

This test was developed for exfoliation testing on certain aluminum alloys. This is followed by 3.

ASTM G85 annex A4 — Sulphur dioxide SO2 salt spray test, cyclic Test specimens are placed in an enclosed chamber, and exposed to 1 of 2 possible changing climate cycles. ASTM G85 annex A3 — seawater acidified test, cyclic Test specimens are placed in an enclosed chamber, and exposed to a changing climate that comprises of the following 2 part repeating cycle. These modifications are referred astn in ASTM G85 as annexes A1 to A5 and are applicable to ferrous and nonferrous metals, and also to organic and inorganic coatings.